new

Get trending papers in your email inbox!

Subscribe

Daily Papers

byAK and the research community

Nov 26

EquiformerV3: Scaling Efficient, Expressive, and General SE(3)-Equivariant Graph Attention Transformers

As SE(3)-equivariant graph neural networks mature as a core tool for 3D atomistic modeling, improving their efficiency, expressivity, and physical consistency has become a central challenge for large-scale applications. In this work, we introduce EquiformerV3, the third generation of the SE(3)-equivariant graph attention Transformer, designed to advance all three dimensions: efficiency, expressivity, and generality. Building on EquiformerV2, we have the following three key advances. First, we optimize the software implementation, achieving 1.75times speedup. Second, we introduce simple and effective modifications to EquiformerV2, including equivariant merged layer normalization, improved feedforward network hyper-parameters, and attention with smooth radius cutoff. Third, we propose SwiGLU-S^2 activations to incorporate many-body interactions for better theoretical expressivity and to preserve strict equivariance while reducing the complexity of sampling S^2 grids. Together, SwiGLU-S^2 activations and smooth-cutoff attention enable accurate modeling of smoothly varying potential energy surfaces (PES), generalizing EquiformerV3 to tasks requiring energy-conserving simulations and higher-order derivatives of PES. With these improvements, EquiformerV3 trained with the auxiliary task of denoising non-equilibrium structures (DeNS) achieves state-of-the-art results on OC20, OMat24, and Matbench Discovery.

Analysis of grid instabilities in particle-in-cell codes based on a meshfree approach

A new method of analyzing grid, or aliasing, instabilities is described, in particle-in-cell (PIC) codes for plasma kinetic theory. It starts with a meshfree approach with N_{p} macroparticles, with N_{p}<infty. Linearization of these equations is done about a uniform density non-drifting equilibrium prescribed by macroparticles on a uniform lattice. Macroparticle positions perturbations are induced about this lattice. The resulting linear equations are analyzed for stability and dispersion relations. The linearized equations are then discretized on a grid of N_{g} points with N_{g} le N_{p}, in both momentum conserving (MCP) and energy conserving (ECP) formulations. For a cold stationary plasma, this leads a dynamical matrix. For ECP, the matrix is symmetric and positive definite (SPD) and immediately shows stability. For MCP, the dynamical matrix is neither symmetric nor positive definite, preventing immediate conclusions on stability. For both MCP and ECP and for a cold stationary plasma, the resulting matrix elements vary relative to the meshfree value, a result of aliasing. This deviation is periodic in the displacement of the particle lattice relative to the grid. In the MCP discretization, eigenvalues occur in complex conjugate pairs for general placement of the particle lattice relative to the grid. These conjugate pairs indicate nonnegative growth rates. The nature of the aliasing is studied and shown to be related to the trapezoidal rule error over the grid. The scaling of the linear growth rates with respect to N_{g} and especially with respect to N_{ppc} is studied. These analytical results are compared with PIC simulations and found to be in excellent agreement. The connection with a cold drifting beam is discussed briefly, specifically, grid-induced instabilities for both the MCP and ECP.

  • 2 authors
·
Sep 30

Electromagnetic drift-kinetic particle-in-cell model with energy and charge conservation for studying finite-$β$ plasmas

The paper proposes a generalization of the fully implicit energy- and charge-conserving electromagnetic particle-in-cell method to the case where the lightest type of plasma particle (electrons) is described in the drift-kinetic approximation. This allows us to remove the very strict time step limitation of this method requiring to resolve the gyrorotation of electrons. Since the drift-kinetic model is only applicable to light particles whose contribution to plasma polarization is small, this model can be further simplified by neglecting the electron polarization drift and including in Maxwell's equations, in addition to the current of gyrocenters, only the magnetization current. In order for such a hybrid model to retain conservative properties in finite-difference form, a method of self-consistent interpolation of nabla B in the mirror force from grid to particle and the magnetization vector from particle to grid is proposed. Unlike existing drift-kinetic models, this model is not limited to considering small perturbations near a given equilibrium, and therefore allows one to study the formation of plasma equilibria in regimes with a finite ratio of plasma to magnetic field pressure. Testing of the parallel code implemented in C++ using the PETSc library confirmed the fulfillment of the finite-difference laws of energy and charge conservation, as well as the ability of the model (in the drift-kinetic version for all types of particles) to correctly reproduce the diamagnetic effect and longitudinal ion-acoustic wave.

  • 3 authors
·
Sep 30

Air Quality and Greenhouse Gas Emissions Assessment of Data Centers in Texas: Quantifying Impacts and Environmental Tradeoffs

This study assesses air quality (AQ) and greenhouse gas (GHG) emissions from the rapid expansion of data centers in Texas, a major hub due to infrastructure, electricity markets, and business conditions. AQ impacts were separated from GHG emissions to clarify sources, regulations, and mitigation strategies. Electricity consumption and cooling systems dominate GHG emissions, with a 10 megawatt data center generating about 37,668 metric tons CO2 annually, while construction materials and IT equipment add substantial embodied emissions. Local AQ impacts, often overlooked, arise from diesel backup generators, construction equipment, and commuting. Generator testing alone can emit about 12 metric tons of NOx annually per facility, worsening ozone issues in regions such as Houston and Dallas-Fort Worth. Mitigation strategies include advanced cooling, renewable energy procurement, cleaner backup power (fuel cells, batteries), sustainable construction, and standardized reporting. ERCOT forecasts project 39 to 78 gigawatts of new data center load by 2030, potentially leading to 170 to 205 million metric tons of annual CO2 emissions. Aggressive adoption of renewables and advanced technologies could cut emissions by 50 to 80 percent, avoiding 85 to 165 million metric tons of CO2. The study identifies research and policy gaps, including the need for cumulative air dispersion modeling, AQ-specific regulations, and mandatory efficiency standards. Findings underscore the importance of aligning Texas digital infrastructure growth with environmental and community health protections.

  • 1 authors
·
Sep 25, 2025

An Introduction to Electrocatalyst Design using Machine Learning for Renewable Energy Storage

Scalable and cost-effective solutions to renewable energy storage are essential to addressing the world's rising energy needs while reducing climate change. As we increase our reliance on renewable energy sources such as wind and solar, which produce intermittent power, storage is needed to transfer power from times of peak generation to peak demand. This may require the storage of power for hours, days, or months. One solution that offers the potential of scaling to nation-sized grids is the conversion of renewable energy to other fuels, such as hydrogen or methane. To be widely adopted, this process requires cost-effective solutions to running electrochemical reactions. An open challenge is finding low-cost electrocatalysts to drive these reactions at high rates. Through the use of quantum mechanical simulations (density functional theory), new catalyst structures can be tested and evaluated. Unfortunately, the high computational cost of these simulations limits the number of structures that may be tested. The use of machine learning may provide a method to efficiently approximate these calculations, leading to new approaches in finding effective electrocatalysts. In this paper, we provide an introduction to the challenges in finding suitable electrocatalysts, how machine learning may be applied to the problem, and the use of the Open Catalyst Project OC20 dataset for model training.

  • 17 authors
·
Oct 14, 2020

Carbon Emissions and Large Neural Network Training

The computation demand for machine learning (ML) has grown rapidly recently, which comes with a number of costs. Estimating the energy cost helps measure its environmental impact and finding greener strategies, yet it is challenging without detailed information. We calculate the energy use and carbon footprint of several recent large models-T5, Meena, GShard, Switch Transformer, and GPT-3-and refine earlier estimates for the neural architecture search that found Evolved Transformer. We highlight the following opportunities to improve energy efficiency and CO2 equivalent emissions (CO2e): Large but sparsely activated DNNs can consume <1/10th the energy of large, dense DNNs without sacrificing accuracy despite using as many or even more parameters. Geographic location matters for ML workload scheduling since the fraction of carbon-free energy and resulting CO2e vary ~5X-10X, even within the same country and the same organization. We are now optimizing where and when large models are trained. Specific datacenter infrastructure matters, as Cloud datacenters can be ~1.4-2X more energy efficient than typical datacenters, and the ML-oriented accelerators inside them can be ~2-5X more effective than off-the-shelf systems. Remarkably, the choice of DNN, datacenter, and processor can reduce the carbon footprint up to ~100-1000X. These large factors also make retroactive estimates of energy cost difficult. To avoid miscalculations, we believe ML papers requiring large computational resources should make energy consumption and CO2e explicit when practical. We are working to be more transparent about energy use and CO2e in our future research. To help reduce the carbon footprint of ML, we believe energy usage and CO2e should be a key metric in evaluating models, and we are collaborating with MLPerf developers to include energy usage during training and inference in this industry standard benchmark.

  • 9 authors
·
Apr 22, 2021

Full Scaling Automation for Sustainable Development of Green Data Centers

The rapid rise in cloud computing has resulted in an alarming increase in data centers' carbon emissions, which now accounts for >3% of global greenhouse gas emissions, necessitating immediate steps to combat their mounting strain on the global climate. An important focus of this effort is to improve resource utilization in order to save electricity usage. Our proposed Full Scaling Automation (FSA) mechanism is an effective method of dynamically adapting resources to accommodate changing workloads in large-scale cloud computing clusters, enabling the clusters in data centers to maintain their desired CPU utilization target and thus improve energy efficiency. FSA harnesses the power of deep representation learning to accurately predict the future workload of each service and automatically stabilize the corresponding target CPU usage level, unlike the previous autoscaling methods, such as Autopilot or FIRM, that need to adjust computing resources with statistical models and expert knowledge. Our approach achieves significant performance improvement compared to the existing work in real-world datasets. We also deployed FSA on large-scale cloud computing clusters in industrial data centers, and according to the certification of the China Environmental United Certification Center (CEC), a reduction of 947 tons of carbon dioxide, equivalent to a saving of 1538,000 kWh of electricity, was achieved during the Double 11 shopping festival of 2022, marking a critical step for our company's strategic goal towards carbon neutrality by 2030.

  • 8 authors
·
Feb 28, 2025

Green Algorithms: Quantifying the carbon footprint of computation

Climate change is profoundly affecting nearly all aspects of life on earth, including human societies, economies and health. Various human activities are responsible for significant greenhouse gas emissions, including data centres and other sources of large-scale computation. Although many important scientific milestones have been achieved thanks to the development of high-performance computing, the resultant environmental impact has been underappreciated. In this paper, we present a methodological framework to estimate the carbon footprint of any computational task in a standardised and reliable way, based on the processing time, type of computing cores, memory available and the efficiency and location of the computing facility. Metrics to interpret and contextualise greenhouse gas emissions are defined, including the equivalent distance travelled by car or plane as well as the number of tree-months necessary for carbon sequestration. We develop a freely available online tool, Green Algorithms (www.green-algorithms.org), which enables a user to estimate and report the carbon footprint of their computation. The Green Algorithms tool easily integrates with computational processes as it requires minimal information and does not interfere with existing code, while also accounting for a broad range of CPUs, GPUs, cloud computing, local servers and desktop computers. Finally, by applying Green Algorithms, we quantify the greenhouse gas emissions of algorithms used for particle physics simulations, weather forecasts and natural language processing. Taken together, this study develops a simple generalisable framework and freely available tool to quantify the carbon footprint of nearly any computation. Combined with a series of recommendations to minimise unnecessary CO2 emissions, we hope to raise awareness and facilitate greener computation.

  • 3 authors
·
Jul 15, 2020

Operational Control of a Multi-energy District Heating System: Comparison of Model-Predictive Control and Rule-Based Control

This study focuses on operational control strategies for a multi-energy District Heating Network (DHN). Two control strategies are investigated and compared: (i) a reactive rule-based control (RBC) and (ii) a model predictive control (MPC). For the purpose of the study a small scale district heating network is modelled using Modelica. The production plant combines a heat pump, a gas boiler and a thermal solar field on the production side with a storage tank for flexibility purposes. On the consumption side, the virtual buildings are aggregated into a single consumer. We use our co-simulation and control platform, called Pegase, to implement the studied strategies. For both strategies the goal is to meet the consumers' demand while satisfying technical constraints. In addition MPC has the objective to minimize the operational costs, taking into account variable electricity prices and availability of solar thermal resource. Different scenarios are also defined and compared to study the effect of the heat plant sizing and forecasting error. The operational cost is reduced when switching from RBC to a MPC. As can be expected, MPC is more efficient when dealing with variable energy costs, intermittent solar energy and storage capabilities. This study also demonstrates how our tools enable an easy coupling of Modelica-based simulation with various control strategies. It especially supports the implementation and validation of complex MPC strategies in an efficient way, and yearly simulations are performed within 20 minutes.

  • 4 authors
·
Jun 17, 2025

Towards an accelerated decarbonization of chemical industry by electrolysis

The transition towards carbon-neutral chemical production is challenging due to the fundamental reliance of the chemical sector on petrochemical feedstocks. Electrolysis-based manufacturing, powered by renewables, is a rapidly evolving technology that might be capable of drastically reducing CO2 emissions from the chemical sector. However, will it be possible to scale up electrolysis systems to the extent necessary to entirely decarbonize all chemical plants? Applying a forward-looking scenario, this perspective estimates how much energy will be needed to power full-scale electrolysis based chemical manufacturing by 2050. A significant gap is identified between the currently planned renewable energy expansion and the energy input necessary to electrify the chemical production: at minimum, the energy required for production of hydrogen and electrolysis of CO2 corresponds to > 50% of all renewable energy that is planned to be available. To cover this gap, strategies enabling a meaningful reduction of the energy input to electrolysis are being discussed from the perspective of both a single electrolysis system and an integrated electro-plant. Several scale-up oriented research priorities are formulated to underpin timely development and commercial availability of described technologies, as well as to explore synergies and support further growth of the renewable energy sector, essential to realize described paradigm shift in chemical manufacturing.

  • 2 authors
·
Jan 7, 2022